MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/19714009231163559

Медицинская библиотека · The neuroradiology journal · 2023

Pediatric low-dose head CT: Image quality improvement using iterative model reconstruction.

Rabinowich Aviad, Shendler Genady, Ben-Sira Liat, Shiran Shelly I

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the differences in pediatric non-contrast low-dose head computed tomography (CT) between filtered-back projection and iterative model reconstruction using objective and subjective image quality evaluation.

METHODS

A retrospective study evaluated children undergoing low-dose non-contrast head CT. All CT scans were reconstructed using both filtered-back projection and iterative model reconstruction. Objective image quality analysis was performed using contrast and signal-to-noise ratios for the supra- and infratentorial brain regions of identical regions of interest on the two reconstruction methods. Two experienced pediatric neuroradiologists evaluated subjective image quality, visibility of structures, and artifacts.

RESULTS

We evaluated 233 low-dose brain CT scans of 148 pediatric patients. There was a ∼2-fold improvement in the contrast-to-noise ratio between gray and white matter in the infra- and supratentorial regions (p < 0.001) using iterative model reconstruction compared to filtered-back projection. The white and gray matter signal-to-noise ratio improved more than 2-fold using iterative model reconstruction (p < 0.001). Furthermore, radiologists graded anatomical details, gray-white matter differentiation, beam hardening artifacts, and image quality using iterative model reconstructions as superior to filtered-back projection reconstructions.

CONCLUSION

Iterative model reconstructions had better contrast-to-noise and signal-to-noise ratios with fewer artifacts in pediatric CT brain scans using low-dose radiation protocols. This image quality improvement was demonstrated in the supra- and infratentorial regions. This method thus comprises an important tool for reducing children's exposure while maintaining diagnostic capability.

Для цитирования: Rabinowich Aviad, Shendler Genady, Ben-Sira Liat, Shiran Shelly I. Pediatric low-dose head CT: Image quality improvement using iterative model reconstruction.. The neuroradiology journal. 2023. DOI: 10.1177/19714009231163559.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.