MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11307-026-02094-9

Медицинская библиотека · Molecular imaging and biology · 2026

Comparison of [18F]DPA-814 with [18F]DPA-714 for TSPO Imaging in an Experimental Model.

van der Bie J, Bakker J, Verschoor E J, Nutma E, Middeldorp J, Beaino W, Kassiou M, Danon J J, Langermans J A M, Windhorst A D, Stammes M A

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: [18F]DPA-714 is a valuable tracer for studying (neuro)inflammation, with well-characterized tracer kinetics and an established imaging window. However, its clinical utility is restricted by the TSPO polymorphism (rs6971), which influences binding affinity in humans. The newly developed tracer [18F]DPA-814 overcomes this limitation and has shown promising results in a preclinical rat model. To further assess its clinical potential, we compared [18F]DPA-814 to [18F]DPA-714 for inflammation imaging in SARS-CoV-2-infected macaques in a longitudinal setting.

PROCEDURES: Dynamic positron emission tomography (PET) imaging was conducted in four healthy macaques to identify the optimal imaging window for [18F]DPA-814. Four additional macaques were infected with SARS-CoV-2 and monitored for 12 months using whole-body PET-computed tomography (CT) with both tracers. Baseline scans were compared to PET-CTs obtained at 4, 9 and 16 days and at 6 and 12 months post-infection, covering the head, thorax and abdomen. Tracer uptake was assessed in several organs.

RESULTS

At baseline, [18F]DPA-814 showed higher lung uptake with minimal washout compared to [18F]DPA-714. Although lung lesions developed after infection, [18F]DPA-814 did not demonstrate lesion-specific uptake, unlike [18F]DPA-714. In the brain, the tracers also displayed divergent uptake patterns despite comparable TSPO levels across animals and regions.

CONCLUSIONS

[18F]DPA-814 exhibits a distinct whole-body distribution, particularly in the lungs and brain, in both naïve and SARS-CoV-2-infected macaques compared with [18F]DPA-714, likely reflecting differences in tracer kinetics. Based on these data, [18F]DPA-814 may not fully replace [18F]DPA-714 for lung and brain imaging, and further studies are required to evaluate its suitability in other anatomical regions.

Для цитирования: van der Bie J, Bakker J, Verschoor E J, Nutma E, Middeldorp J, Beaino W, Kassiou M, Danon J J, Langermans J A M, Windhorst A D, Stammes M A. Comparison of [18F]DPA-814 with [18F]DPA-714 for TSPO Imaging in an Experimental Model.. Molecular imaging and biology. 2026. DOI: 10.1007/s11307-026-02094-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.