Goniometric evaluation of the spinal sagittal curves in children and adolescents: A reliability study.
Аннотация
BACKGROUND
Gold standard for spine deformities assessment is X rays, but the procedure bears a risk of exposure.
OBJECTIVE
To investigate intra-rater and inter-rater reliability of a pocket compass needle goniometer (IncliMed®, University of Padua) to non-invasively evaluate spine curves in children and adolescents.
METHODS
Prospective reliability study in a paediatric population (mean age 12.5 years ± 2.5). Children with spine deformities (Scheuermann's or postural kyphosis, idiopathic scoliosis) and healthy controls were included. Two physician measured spinal curves with the surface goniometer IncliMed® within a temporal range of 10 minutes. Participants were re-tested after a mean of 28 days for the intra-rater study. Agreement limit and coefficient of repeatability were calculated according to the linear regression analysis; the Bland and Altman method was applied to obtain average of differences and standard error of the mean of the differences.
RESULTS
One hundred and thirty-nine subjects participated to the inter-rater reliability assessment; 30 to the intra-rater reliability assessment. Inter-observer variability for IncliMed® measurements was ± 11° both for kyphosis and for lordosis. The intra-observer variability for kyphosis and lordosis measurements was ± 11° and ± 12°.
CONCLUSIONS
IncliMed® is a reliable, non-invasive tool to screen and monitor spinal curves in paediatric populations.
Другие публикации по теме
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.