DOI 10.1097/scs.0000000000011879
To Burr or Not to Burr: Preventing Unintended Fractures During Cranial Vault Reshaping.
Аннотация
PURPOSE: This study evaluates whether burr holes reduce fracture risk during craniosynostosis surgery by examining their effect on stress distribution at osteotomy endpoints.
METHODS
Sixteen macaque calvaria samples (mean age: 8.5 years) were sectioned into 30 × 19 mm pieces. The experimental group (n=8) included burr holes at osteotomy endpoints; the control group (n=8) did not. Finite element analysis optimized osteotomy and fixture hole placement. Mechanical testing utilized an MTS® 30/G universal testing machine. Groups were compared via independent samples t test.
RESULTS
The addition of burr holes did not significantly affect load-bearing capacity or displacement of the specimens. Mean peak load was 70.85 N (SD 22.30) in the burr-hole group versus 69.73 N (SD 20.12) in the control group ( P =0.9175). Mean displacement was identical at 1.26 mm (burr-hole SD 0.27 mm; control SD 0.38 mm; P =0.9924). Fracture toughness (Kc) was also comparable between groups: burr-hole 583.1 kJ/m² (SD 165.6) versus control 584.7 kJ/m² (SD 147.9) ( P =0.9840).
CONCLUSION
Burr holes did not significantly impact load-bearing capacity, displacement, or fracture toughness in macaque calvarial bone, contrasting with isotropic materials (eg, steel) where stress relievers reduce fracture risk. Future research should explore alternative stress-relief osteotomy designs to minimize intraoperative fracture risks.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.