Interobserver and intraobserver reliability of determining the deformity angular ratio in severe pediatric deformity curves.

Zuckerman Scott L, Lenke Lawrence G, Cerpa Meghan, Kelly Michael P, Yaszay Burt, Sponseller Paul, Erickson Mark, Garg Sumeet, Pahys Joshua, Cahill Patrick, Sides Brenda, Gupta Munish, Fox Pediatric Spinal Deformity Study Group

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STUDY

DESIGN

Cross-sectional reliability study.

OBJECTIVE

The deformity angular ratio (DAR) is a means of quantifying magnitude of the coronal (C-DAR) and sagittal (S-DAR) plane of deformity curves to produce a total DAR (T-DAR). It has been shown to predict the risk of spinal cord monitoring alerts and actual neurologic deficits. We sought to assess the reliability of determining the C-DAR and S-DAR among pediatric spinal deformity surgeons.

METHODS

Twelve preoperative anterior-posterior (AP) and lateral X-rays from the Fox multi-center pediatric deformity study were de-identified and sent to7 pediatric spinal deformity surgeons. Each surgeon measured: coronal/sagittal Cobb angles, upper/lower endplate vertebrae (UEV/LEV), apices, and number of vertebrae included in the main curve. The C-DAR and S-DAR were then calculated by dividing the Cobb angles by the number of vertebrae included in the curve. Intra- and interobserver reliability was calculated using interclass correlation (ICC).

RESULTS

The mean C-DAR was 14.9 (range 1.3-51.5) with a mean Cobb angle of 88.8° (range 15.0-163.0) over a mean of 7.5 (range 2.0-14.0) levels. The mean S-DAR was 8.6 (range 1.0-19.6), with a mean Cobb angle of 68.0° (range 10.0-137.0) over a mean of 7.5 (range 3-11) levels. The intraobserver reliability of the C-DAR was ICC = 0.908 (range 0.846-0.960) and the S-DAR 0.914 (range 0.815-0.961). The interobserver reliability of the C-DAR was ICC = 0.868 (range 0.846-0.938), and the S-DAR was ICC = 0.848 (range 0.815-0.961). Despite poor reliability among UEV, LEV, and apex selection (aggregated range 0.340-0.724), the C-DAR and S-DAR were demonstrated to be reliable in our study

CONCLUSIONS

Reliability was good to excellent for C-DAR and S-DAR, despite poor to moderate reliability among UEV, LEV, and apex selection. These data support the use of the C-DAR, S-DAR, and combined T-DAR as a means of quantifying deformity magnitude.

Для цитирования: Zuckerman Scott L, Lenke Lawrence G, Cerpa Meghan, Kelly Michael P, Yaszay Burt, Sponseller Paul, Erickson Mark, Garg Sumeet, Pahys Joshua, Cahill Patrick, Sides Brenda, Gupta Munish, Fox Pediatric Spinal Deformity Study Group. Interobserver and intraobserver reliability of determining the deformity angular ratio in severe pediatric deformity curves.. Spine deformity. 2020. DOI: 10.1007/s43390-020-00239-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.