MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/10.641334

Медицинская библиотека · IEEE transactions on bio-medical engineering · 1997

Parametric representation and screening of knee joint vibroarthrographic signals.

Rangayyan R M, Krishnan S, Bell G D, Frank C B, Ladly K O

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

We have been investigating analysis of knee joint vibration or vibroarthrographic (VAG) signals as a potential tool for noninvasive diagnosis and monitoring of cartilage pathology. In this paper, we present a comprehensive comparative study of different parametric representations of VAG signals. Dominant poles and cepstral coefficients were derived from autoregressive models of adaptively segmented VAG signals. Signal features and a few clinical features were used as feature vectors in pattern classification experiments based on logistic regression analysis and the leave-one-out method. The results using 51 normal and 39 abnormal signals indicated the superior performance of cepstral coefficients in VAG signal classification with an accuracy rate of 75.6%. With 51 normal and 20 abnormal signals limited to chondromalacia patella, cepstral coefficients again gave the highest accuracy rate of 85.9%.

Для цитирования: Rangayyan R M, Krishnan S, Bell G D, Frank C B, Ladly K O. Parametric representation and screening of knee joint vibroarthrographic signals.. IEEE transactions on bio-medical engineering. 1997. DOI: 10.1109/10.641334.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.