MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bpo.0000000000000235

Медицинская библиотека · Journal of pediatric orthopedics · 2015

Hybrid fixation with sublaminar polyester bands in the treatment of neuromuscular scoliosis: a comparative analysis.

Albert Michael C, LaFleur Brett C

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Segmental spinal instrumentation with Luque wire fixation has been the standard treatment of neuromuscular scoliosis for >30 years. More recently, pedicle screw constructs have become the most widely utilized method of posterior spinal fixation; however, they are associated with complications such as implant malposition. We report the use of polyester bands and clamps utilized with pedicle screws in a hybrid fixation construct in the treatment of neuromuscular scoliosis.

METHODS

A retrospective review was conducted of 115 pediatric spinal deformity cases between 2008 and 2010 at a single center performed by a single surgeon. Intraoperative and postoperative complications were recorded. Radiographs were reviewed preoperatively and at the latest follow-up. A systematic review of the literature was conducted. Data from case series reporting outcomes of sublaminar wires and all-pedicle screw constructs in the treatment of neuromuscular scoliosis were compared with outcomes of the present study.

RESULTS

Twenty-nine patients with neuromuscular scoliosis who underwent segmental spinal instrumentation with a hybrid construct including sublaminar bands and pedicle screws were included. There was an average follow-up of 29 months (range, 12 to 40 mo). The average postoperative correction of coronal balance was 69% (range, 24 to 71 degrees). Sagittal balance was corrected to within 2 cm of the C7 plumbline in 97% of patients. The loss of coronal and sagittal correction at latest follow-up was 0% and 2%, respectively. There were 2 intraoperative clamp failures of the 398 implants (0.5%). There were 2 major (6.9%) and 7 minor (24%) complications in 7 patients (24% overall). These results compared favorably to previous case series of sublaminar wire and all-pedicle screw fixation techniques.

CONCLUSIONS

The polyester band technique is an excellent adjunct in the correction of spinal deformity in patients with neuromuscular scoliosis. Sublaminar bands utilized in a hybrid construct appear to be safe, can achieve corrections equivalent to all-pedicle screw constructs, and may decrease the potential complications associated with every level transpedicular fixation in the patient with a highly dysmorphic and osteoporotic spine.

LEVEL OF EVIDENCE: Level IV: cohort study.

Для цитирования: Albert Michael C, LaFleur Brett C. Hybrid fixation with sublaminar polyester bands in the treatment of neuromuscular scoliosis: a comparative analysis.. Journal of pediatric orthopedics. 2015. DOI: 10.1097/bpo.0000000000000235.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.