PURPOSE: The step-cut osteotomy has been recognized as a valuable approach for addressing cubitus varus deformity, albeit one that necessitates technical proficiency. This study aims to evaluate the efficacy of the modified step-cut osteotomy technique in conjunction with patient-specific instruments by clinical and radiological assessment.

METHODS: We conducted a retrospective review of patients who underwent modified step-cut osteotomy with the use of patient-specific instruments in conjunction with Kirschner wires fixation for the correction of cubitus varus deformity between April 2016 and April 2022. Follow-up was performed for a minimum of two years, during which pre-operative and post-operative clinical and radiological parameters were compared.

RESULTS: Fifteen patients were enrolled in this study. The mean pre-operative humeral-elbow-wrist (HEW) of the affected side was -21.7° (ranging from -14° to -34°), while the normal side was 9.4° (ranging from 5° to 15°). The post-operation HEW of affected side was 9° (ranging from 4° to 16°). There was no significant difference between the normal side and affected side after operation (p = 0.74). Pre-operative range of motion in the affected side was 130°, while the post-operative range of motion was 132°. Fourteen patients (93.3%) were pleased with the overall appearance of their elbow. None lazy-S deformity was observed in these cases. There were no major complications.

CONCLUSION: The modified step-cut osteotomy technique, utilizing patient-specific instrument in conjunction with Kirschner wires fixation was found to be a safe, reliable, and technically easy procedure for correcting cubitus varus deformity.