MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.wneu.2024.04.091

Медицинская библиотека · World neurosurgery · 2024

Artificial Intelligence Assistance for the Measurement of Full Alignment Parameters in Whole-Spine Lateral Radiographs.

Landriel Federico, Franchi Bruno Cruz, Mosquera Candelaria, Lichtenberger Fernando Padilla, Benitez Sonia, Aineseder Martina, Guiroy Alfredo, Hem Santiago

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Measuring spinal alignment with radiological parameters is essential in patients with spinal conditions likely to be treated surgically. These evaluations are not usually included in the radiological report. As a result, spinal surgeons commonly perform the measurement, which is time-consuming and subject to errors. We aim to develop a fully automated artificial intelligence (AI) tool to assist in measuring alignment parameters in whole-spine lateral radiograph (WSL X-rays).

METHODS

We developed a tool called Vertebrai that automatically calculates the global spinal parameters (GSPs): Pelvic incidence, sacral slope, pelvic tilt, L1-L4 angle, L4-S1 lumbo-pelvic angle, T1 pelvic angle, sagittal vertical axis, cervical lordosis, C1-C2 lordosis, lumbar lordosis, mid-thoracic kyphosis, proximal thoracic kyphosis, global thoracic kyphosis, T1 slope, C2-C7 plummet, spino-sacral angle, C7 tilt, global tilt, spinopelvic tilt, and hip odontoid axis. We assessed human-AI interaction instead of AI performance alone. We compared the time to measure GSP and inter-rater agreement with and without AI assistance. Two institutional datasets were created with 2267 multilabel images for classification and 784 WSL X-rays with reference standard landmark labeled by spinal surgeons.

RESULTS

Vertebrai significantly reduced the measurement time comparing spine surgeons with AI assistance and the AI algorithm alone, without human intervention (3 minutes vs. 0.26 minutes; P < 0.05). Vertebrai achieved an average accuracy of 83% in detecting abnormal alignment values, with the sacral slope parameter exhibiting the lowest accuracy at 61.5% and spinopelvic tilt demonstrating the highest accuracy at 100%. Intraclass correlation analysis revealed a high level of correlation and consistency in the global alignment parameters.

CONCLUSIONS

Vertebrai's measurements can accurately detect alignment parameters, making it a promising tool for measuring GSP automatically.

Для цитирования: Landriel Federico, Franchi Bruno Cruz, Mosquera Candelaria, Lichtenberger Fernando Padilla, Benitez Sonia, Aineseder Martina, Guiroy Alfredo, Hem Santiago. Artificial Intelligence Assistance for the Measurement of Full Alignment Parameters in Whole-Spine Lateral Radiographs.. World neurosurgery. 2024. DOI: 10.1016/j.wneu.2024.04.091.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.