CASE: A 70-year-old man presented with a left pilon fracture after a 10-foot fall from a ladder. The severe amount of comminution, joint destruction, and impaction from this injury eventually resulted in a tibiotalar fusion. Owing to multiple tibiotalar fusion plates not being long enough to span the extent of the fracture, a tensioned proximal humerus plate was used as an alternative.

CONCLUSION

We do not endorse the off-label use of a tensioned proximal humerus plate for all tibiotalar fusions; however, we do believe that this is a useful technique in certain situations with large zones of distal tibial comminution.

Для цитирования: Aneja Arun, Sneed Chandler R, Pectol Richard W, Kavolus Matthew W, Foster Jeffrey A, Kinchelow Daria L. An Off-Label Use of a Tensioned Proximal Humerus Plate for Tibiotalar Fusion: A Case Report.. JBJS case connector. 2022. DOI: 10.2106/jbjs.cc.22.00576.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.