MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3899/jrheum.141236

Медицинская библиотека · The Journal of rheumatology · 2015

Joint Aspiration for Acute Hemarthrosis in Children Receiving Factor VIII Prophylaxis for Severe Hemophilia: 11-year Safety Data.

Manners Prudence J, Price Peter, Buurman Danika, Lewin Brittany, Smith Brooke, Cole Catherine H

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The aims of this study were (1) to document the prevalence of acute hemarthrosis in a cohort of 46 boys with severe hemophilia A receiving full primary prophylaxis in Western Australia (WA), and (2) to investigate the safety of the WA protocol over 11 years for management of hemarthrosis.

METHODS

Case review. The WA protocol involves a pediatric rheumatologist washing out all acute hemarthrosis of large joints promptly and then instilling intraarticular (IA) corticosteroids.

RESULTS

This study showed that joint bleeds occurred in 22 boys of 46 (47.8%). In over 11 years, 84 washouts were performed on 32 joints in 22 boys. No adverse events occurred. Fifteen of 22 boys had normal joints with a Hemophilic Joint Health Score = 0. Fifteen boys who had had all hemarthrosis washed out had clinically normal joints (100%). Seven boys had sustained joint damage prior to full instigation of the protocol, each having had documented hemarthrosis without aspiration. Parents needed to understand that joint bleeds constituted an emergency.

CONCLUSION

Of our cohort, 47.8% of patients with severe hemophilia receiving prophylaxis developed joint bleeding. The WA protocol is safe. There is evidence suggesting joint outcomes of hemophilic patients having hemarthrosis despite factor VIII prophylaxis may be much improved if there is access to a center using a procedure similar to the WA protocol.

Для цитирования: Manners Prudence J, Price Peter, Buurman Danika, Lewin Brittany, Smith Brooke, Cole Catherine H. Joint Aspiration for Acute Hemarthrosis in Children Receiving Factor VIII Prophylaxis for Severe Hemophilia: 11-year Safety Data.. The Journal of rheumatology. 2015. DOI: 10.3899/jrheum.141236.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.