BioGlue for prevention of postoperative cerebrospinal fluid leaks in transsphenoidal surgery: A case series.

Dusick Joshua R, Mattozo Carlos A, Esposito Felice, Kelly Daniel F

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The efficacy of BioGlue (CryoLife, Inc, Atlanta, Ga) surgical adhesive in transsphenoidal surgery was assessed as an adjunct in the prevention of postoperative CSF leaks.

METHODS

All patients in whom BioGlue was used for an intraoperative skull base reconstruction were retrospectively identified. Intraoperative CSF leaks were graded according to size (grade 1, small weeping leak without obvious diaphragmatic defect; grade 2, moderate leak with a definite diaphragmatic defect; grade 3, large diaphragmatic and/or dural defect). CSF leak repair was tailored to CSF leak grade. BioGlue was applied as a reinforcement over collagen sponge as the last layer of the repair.

RESULTS

Over 28 months, a total of 282 patients underwent endonasal surgery. Of these patients, 124 (79 women; age range, 8-84 years), in 128 procedures, had an intraoperative CSF leak repair reinforced with BioGlue. Pathology included 80 pituitary adenomas, 11 craniopharyngiomas, 7 Rathke's cleft cysts, 6 chordomas, 5 meningiomas, 4 spontaneous CSF leaks, 3 arachnoid cysts, and 8 other parasellar pathologies. There were 62 (48.4%) grade 1, 41 (32.0%) grade 2, and 25 (19.5%) grade 3 leak repairs. The overall repair failure rate was 1.6% (2 cases), with the failures occurring in patients with grade 3 leaks, including 1 who developed meningitis; there was no failure of grades 1 and 2 leaks. The 2 failures were attributed largely to technical aspects of the repair rather than to failure of BioGlue per se.

CONCLUSIONS

BioGlue appears to be an effective adjunct in preventing postoperative CSF leaks after transsphenoidal surgery. However, careful attention to technical details of the repair is still required to prevent failures, especially when closing large dural and diaphragmatic defects.

Для цитирования: Dusick Joshua R, Mattozo Carlos A, Esposito Felice, Kelly Daniel F. BioGlue for prevention of postoperative cerebrospinal fluid leaks in transsphenoidal surgery: A case series.. Surgical neurology. 2006. DOI: 10.1016/j.surneu.2006.06.043.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.