MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00586-022-07427-0

Медицинская библиотека · European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2022

Pedicle screw placement safety with the aid of patient-specific guides in a case series of patients with thoracic scoliosis.

Mohar Janez, Valič Matej, Podovšovnik Eva, Mihalič Rene

Наблюдательное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: Pedicle screw (PS) placement in thoracic scoliotic deformities can be challenging due to altered vertebral anatomy; malposition can result in severe functional disability or inferior construct stability. Three-dimensional (3D) printed patient-specific guides (PSGs) have been recently used to supplement other PS placement techniques. We conducted a single-center, retrospective observational study to assess the accuracy of PS placement using PSGs in a consecutive case series of pediatric and adult patients with thoracic scoliosis.

METHODS

We analyzed the data of patients with thoracic scoliosis who underwent PS placement using 3D-printed PSG as a vertebral cannulation aid between June 2013 and July 2018. PS positions were determined via Gertzbein-Robbins (GR) and Heary classifications on computed tomography images. We determined the concordance of actual and preoperatively planned PS positions and defined the technique learning curve using a receiver-operating characteristic (ROC) curve.

RESULTS

We performed 362 thoracic PS placement procedures in 39 consecutive patients. We classified 352 (97.2%), 2 (0.6%), and 8 (2.2%) screws as GR grades 0 (optimal placement), I, and II, respectively. The average instrumented PS entry point offsets on the X- and Y-axes were both 0.8 mm, and the average differences in trajectory between the planned and the actual screw placements on the oblique sagittal and oblique transverse planes were 2.0° and 2.4°, respectively. The learning process was ongoing until the first 12 PSs were placed.

CONCLUSIONS

The accuracy of PS placement using patient-specific 3D templates in our case series exceeds the accuracies of established thoracic PS placement techniques.

Для цитирования: Mohar Janez, Valič Matej, Podovšovnik Eva, Mihalič Rene. Pedicle screw placement safety with the aid of patient-specific guides in a case series of patients with thoracic scoliosis.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2022. DOI: 10.1007/s00586-022-07427-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.