DOI 10.4085/1062-6050-50.5.06

Медицинская библиотека · Journal of athletic training · 2015

Noise-Enhanced Eversion Force Sense in Ankles With or Without Functional Instability.

Ross Scott E, Linens Shelley W, Wright Cynthia J, Arnold Brent L

Clinical StudyСтатьяПеревод в очереди

Аннотация

CONTEXT: Force sense impairments are associated with functional ankle instability. Stochastic resonance stimulation (SRS) may have implications for correcting these force sense deficits.

OBJECTIVE

To determine if SRS improved force sense.

DESIGN

Case-control study.

SETTING

Research laboratory.

PATIENTS OR OTHER

PARTICIPANTS

Twelve people with functional ankle instability (age = 23 ± 3 years, height = 174 ± 8 cm, mass = 69 ± 10 kg) and 12 people with stable ankles (age = 22 ± 2 years, height = 170 ± 7 cm, mass = 64 ± 10 kg).

INTERVENTION(S): The eversion force sense protocol required participants to reproduce a targeted muscle tension (10% of maximum voluntary isometric contraction). This protocol was assessed under SRSon and SRSoff (control) conditions. During SRSon, random subsensory mechanical noise was applied to the lower leg at a customized optimal intensity for each participant.

MAIN OUTCOME MEASURE(S): Constant error, absolute error, and variable error measures quantified accuracy, overall performance, and consistency of force reproduction, respectively.

RESULTS

With SRS, we observed main effects for force sense absolute error (SRSoff = 1.01 ± 0.67 N, SRSon = 0.69 ± 0.42 N) and variable error (SRSoff = 1.11 ± 0.64 N, SRSon = 0.78 ± 0.56 N) (P < .05). No other main effects or treatment-by-group interactions were found (P > .05).

CONCLUSIONS

Although SRS reduced the overall magnitude (absolute error) and variability (variable error) of force sense errors, it had no effect on the directionality (constant error). Clinically, SRS may enhance muscle tension ability, which could have treatment implications for ankle stability.

Для цитирования: Ross Scott E, Linens Shelley W, Wright Cynthia J, Arnold Brent L. Noise-Enhanced Eversion Force Sense in Ankles With or Without Functional Instability.. Journal of athletic training. 2015. DOI: 10.4085/1062-6050-50.5.06.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.