MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0272555

Медицинская библиотека · PloS one · 2022

Long-term outcome of tibial plateau leveling osteotomy using an antimicrobial silver-based coated plate in dogs.

Pagès Geoffrey, Hammer Meike, Grand Jean-Guillaume, Irubetagoyena Iban

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate long-term outcome using the BioMedtrix™ TPLO Curve® plate in dogs with cranial cruciate ligament disease (CrCLd) treated by tibial plateau leveling osteotomy (TPLO).

STUDY

DESIGN

Retrospective case study.

ANIMALS: Dogs (n = 323, 337 stifles).

METHODS

Medical records were searched for dogs presented with CrCLd and treated by TPLO with the BioMedtrix™ TPLO Curve® plate for 3.5 mm screws between March 2018 and December 2020. Tibial plateau angles (TPA) were measured on preoperative, postoperative, and follow-up radiographs. Changes in TPA between postoperative and follow-up radiographs (ModTPA) were calculated. Radiographic bone healing was scored. Complications were evaluated. Surgical site infections (SSI) were compared to a control group of dogs treated with the Synthes™ TPLO plate between January and December 2017. Owners of both groups were contacted by telephone at least 1 year postoperatively.

RESULTS

The BioMedtrix™ group was composed of 237 dogs (248 stifles), the control group was composed of 86 dogs (89 stifles). In the BioMedtrix™ group, radiographic follow-up was performed at a median of 48 days. Average ModTPA was 1.2°. Bone healing was graded as complete, good, poor, and none in 18%, 62%, 20%, and 0%, respectively. At a median of 786 days postoperatively, minor and major postoperative complications were observed in 6 (2.4%) and 32 (12.9%) cases in this group, respectively. During the first year following the surgery, 23 (9.3%) and 12 (13.5%) cases suffered a SSI, of which 12 (4.8%) and 7 (7.9%) had their implant explanted in the BioMedtrix™ group and the control group, respectively. There was no significant difference between groups for SSI and implant explantations (p = 0.31 and p = 0.29, respectively).

CONCLUSION

The BioMedtrix™ TPLO Curve® plate provided a reliable fixation system for osteotomy healing after TPLO. Bone healing and long-term complication rates were similar to previous studies using other implants. SSI rates were similar between the BioMedtrix™ group and the control group. The antimicrobial HyProtect® coating of the plate did not reduce SSI in this study.

CLINICAL SIGNIFICANCE: The BioMedtrix™ TPLO Curve® plate can be safely used for TPLO. The value of the antimicrobial HyProtect® coating of the plate may be questioned, as SSI rate was not lower in this study compared to the control group or previous reports.

Для цитирования: Pagès Geoffrey, Hammer Meike, Grand Jean-Guillaume, Irubetagoyena Iban. Long-term outcome of tibial plateau leveling osteotomy using an antimicrobial silver-based coated plate in dogs.. PloS one. 2022. DOI: 10.1371/journal.pone.0272555.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.