m+Medelevator.RU
← Поиск публикаций
Veterinary surgery : VS · 2014

Accuracy of tibial osteotomy placement using 2 different tibial plateau leveling osteotomy jigs.

Оценочное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tan Christopher J, Bergh Mary Sarah, Schembri Mark A, Johnson Kenneth A

Аннотация

OBJECTIVE: To report the accuracy of osteotomy position in dogs undergoing tibial plateau leveling osteotomy (TPLO) and to evaluate the effect of 2 different TPLO jig and saw systems on tibial osteotomy position.

STUDY DESIGN: Retrospective case series.

ANIMALS: Dogs (n = 124; 134 TPLO).

METHODS: Medical records (2004-2005; 2008-2011) and stifle radiographs of 2 groups of dogs that had TPLO to treat cranial cruciate ligament disease were reviewed. One group had a TPLO performed using an alignment jig system alone (Slocum group), whilst in the other group, an alignment jig system combined with a saw guide (Synthes group) was used. Postoperative radiographs were examined and the distance and direction of the centroid of the osteotomy was compared to the intended osteotomy position.

RESULTS: The absolute distance of eccentricity (DOE) in the Slocum group (5.6 ± 2.5 mm) was significantly greater than that of the Synthes group (3.4 ± 1.8 mm; P < .01). DOE was caudal and distal in 79% of cases.

CONCLUSIONS: Most tibial osteotomies were centered at a point distal and caudal to the intended osteotomy position. Use of a TPLO system with a saw guide was associated with more accurate placement of the osteotomy and more accurate leveling of the tibial plateau.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049