Accuracy of tibial osteotomy placement using 2 different tibial plateau leveling osteotomy jigs.

Tan Christopher J, Bergh Mary Sarah, Schembri Mark A, Johnson Kenneth A

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To report the accuracy of osteotomy position in dogs undergoing tibial plateau leveling osteotomy (TPLO) and to evaluate the effect of 2 different TPLO jig and saw systems on tibial osteotomy position.

STUDY

DESIGN

Retrospective case series.

ANIMALS: Dogs (n = 124; 134 TPLO).

METHODS

Medical records (2004-2005; 2008-2011) and stifle radiographs of 2 groups of dogs that had TPLO to treat cranial cruciate ligament disease were reviewed. One group had a TPLO performed using an alignment jig system alone (Slocum group), whilst in the other group, an alignment jig system combined with a saw guide (Synthes group) was used. Postoperative radiographs were examined and the distance and direction of the centroid of the osteotomy was compared to the intended osteotomy position.

RESULTS

The absolute distance of eccentricity (DOE) in the Slocum group (5.6 ± 2.5 mm) was significantly greater than that of the Synthes group (3.4 ± 1.8 mm; P < .01). DOE was caudal and distal in 79% of cases.

CONCLUSIONS

Most tibial osteotomies were centered at a point distal and caudal to the intended osteotomy position. Use of a TPLO system with a saw guide was associated with more accurate placement of the osteotomy and more accurate leveling of the tibial plateau.

Для цитирования: Tan Christopher J, Bergh Mary Sarah, Schembri Mark A, Johnson Kenneth A. Accuracy of tibial osteotomy placement using 2 different tibial plateau leveling osteotomy jigs.. Veterinary surgery : VS. 2014. DOI: 10.1111/j.1532-950x.2014.12173.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.