Management of bronchomalacia in infants post-cardiac surgery using synchronized nasal DuoPAP: A novel technology.
Аннотация
BACKGROUND
Tracheo-bronchomalacia (TBM) is the weakness in the structural integrity of the cartilaginous ring and arch. It may occur in isolation with prematurity or secondarily in association with various congenital anomalies. Bronchomalacia is more commonly associated with congenital heart diseases. The conventional treatment options include positive pressure ventilation with or without tracheostomy, surgical correction of external compression and airway stenting.
AIM: To use "synchronized" nasal Dual positive airway pressure (DuoPAP), a non-invasive mode of ventilation as an alternative treatment option for bronchomalacia to avoid complications associated with conventional treatment modalities.
STUDY
DESIGN
Prospective observational study conducted in Army Hospital Research and Referral from Jul 2019 to Dec 2020.
MATERIAL AND
METHODS
We diagnosed seven cases of TBM post-cardiac surgery at our institute, incidence of 4.2%. Four infants were diagnosed with left sided bronchomalacia, 2 were diagnosed with right sided bronchomalacia and one with tracheomalacia. Those infants were managed by "synchronized" nasal DuoPAP, a first in ventilation technology by Fabian Therapy Evolution ventilator (Acutronic, Switzerland).
RESULTS
All seven infants showed significant improvement with synchronized nasal DuoPAP both clinically as well as radiologically. None of the infant required tracheostomy and discharged to home successfully.
CONCLUSION
The synchronized nasal DuoPAP is a low cost and effective treatment option for infants with TBM. It could be attributed to synchronization of the breaths leading to better tolerance and compliance in paediatric age group.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.