MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3171/2017.3.spine16357

Медицинская библиотека · Journal of neurosurgery. Spine · 2017

Sagittal alignment and complications following lumbar 3-column osteotomy: does the level of resection matter?

Ferrero Emmanuelle, Liabaud Barthelemy, Henry Jensen K, Ames Christopher P, Kebaish Khaled, Mundis Gregory M, Hostin Richard, Gupta Munish C, Boachie-Adjei Oheneba, Smith Justin S, Hart Robert A, Obeid Ibrahim, Diebo Bassel G, Schwab Frank J, Lafage Virginie

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVE Three-column osteotomy (3CO) is a demanding technique that is performed to correct sagittal spinal malalignment. However, the impact of the 3CO level on pelvic or truncal sagittal correction remains unclear. In this study, the authors assessed the impact of 3CO level and postoperative apex of lumbar lordosis on sagittal alignment correction, complications, and revisions. METHODS In this retrospective study of a multicenter spinal deformity database, radiographic data were analyzed at baseline and at 1- and 2-year follow-up to quantify spinopelvic alignment, apex of lordosis, and resection angle. The impact of 3CO level and apex level of lumbar lordosis on the sagittal correction was assessed. Logistic regression analyses were performed, controlling for cofounders, to investigate the effects of 3CO level and apex level on intraoperative and postoperative complications as well as on the need for subsequent revision surgery. RESULTS A total of 468 patients were included (mean age 60.8 years, mean body mass index 28.1 kg/m2); 70% of patients were female. The average 3CO resection angle was 25.1° and did not significantly differ with regard to 3CO level. There were no significant correlations between the 3CO level and amount of sagittal vertical axis or pelvic tilt correction. The postoperative apex level significantly correlated with greater correction of pelvic tilt (2° per more caudal level, R = -0.2, p = 0.006). Lower-level 3CO significantly correlated with revisions for pseudarthrosis (OR = 3.88, p = 0.001) and postoperative motor deficits (OR = 2.02, p = 0.026). CONCLUSIONS In this study, a more caudal lumbar 3CO level did not lead to greater sagittal vertical axis correction. The postoperative apex of lumbar lordosis significantly impacted pelvic tilt. 3CO levels that were more caudal were associated with more postoperative motor deficits and revisions.

Для цитирования: Ferrero Emmanuelle, Liabaud Barthelemy, Henry Jensen K, Ames Christopher P, Kebaish Khaled, Mundis Gregory M, Hostin Richard, Gupta Munish C, Boachie-Adjei Oheneba, Smith Justin S, Hart Robert A, Obeid Ibrahim, Diebo Bassel G, Schwab Frank J, Lafage Virginie. Sagittal alignment and complications following lumbar 3-column osteotomy: does the level of resection matter?. Journal of neurosurgery. Spine. 2017. DOI: 10.3171/2017.3.spine16357.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.