[Case report : usefulness of the airwayscope for difficult intubations in a pediatric patients with Coffin-Siris syndrome].
Аннотация
We experienced management of general anesthesia in a patients with Coffin-Siris syndrome (CS syndrome) which is an autosomal dominant disorder characterized by mental retardation, growth failure, hypoplasia of the fifth finger's distal phalanx and limb, and syndrome-specific facial appearance. Anesthesia was induced by sevoflurane by mask. After obtaining muscle relaxation by rocuronium, laryngoscopy by Machintosh #2 failed to reveal the vocal cord. However, the vocal cord was revealed by AirwayScope (AWS) for the pediatrics and then tracheal intubation was successful. Surgical procedures and anes-thetic management were performed uneventfully. This case demonstrates usefulness of AWS in pediatric patients with difficult intubation.