MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00007632-200010150-00016

Медицинская библиотека · Spine · 2000

Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion.

Rampersaud Y R, Foley K T, Shen A C, Williams S, Solomito M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STUDY

DESIGN

In vitro study to determine occupational radiation exposure during lumbar fluoroscopy.

OBJECTIVES

To assess radiation exposure to the spine surgeon during fluoroscopically assisted thoracolumbar pedicle screw placement.

SUMMARY OF BACKGROUND DATA: Occupational radiation exposure during a variety of fluoroscopically assisted musculoskeletal procedures has been previously evaluated. No prior study has assessed fluoroscopy-related radiation exposure to the spine surgeon.

METHODS

Bilateral pedicle screw placement (T11-S1) was performed in six cadavers using lateral fluoroscopic imaging. Radiation dose rates to the surgeon's neck, torso, and dominant hand were measured with dosimeter badges and thermolucent dosimeter (TLD) rings. Radiation levels were also quantified at various distances from the dorsal lumbar surface using an ion chamber radiation survey meter.

RESULTS

The mean dose rate to the neck was 8.3 mrem/min. The dose rate to the torso was greatest when the surgeon was positioned ipsilateral to the beam source (53.3 mrem/min, compared with 2.2 mrem/min on the contralateral side). The average hand dose rate was 58.2 mrem/min. A significant increase in hand dose rate was associated with placement of screws ipsilateral to the beam source (P = 0.0005) and larger specimens (P = 0.0007). Radiation levels significantly decreased as distance from the beam source and dorsal body surface increased. The greatest levels of radiation were noted on the side where the primary radiograph beam entered the cadaver.

CONCLUSION

Fluoroscopically assisted thoracolumbar pedicle screw placement exposes the spine surgeon to significantly greater radiation levels than other, nonspinal musculoskeletal procedures that involve the use of a fluoroscope. In fact, dose rates are up to 10-12 times greater. Spine surgeons performing fluoroscopically assisted thoracolumbar procedures should monitor their annual radiation exposure. Measures to reduce radiation exposure and surgeon awareness of high-exposure body and hand positions are certainly called for.

Для цитирования: Rampersaud Y R, Foley K T, Shen A C, Williams S, Solomito M. Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion.. Spine. 2000. DOI: 10.1097/00007632-200010150-00016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.