Jerks are useful: extracting pulse rate from wrist-placed accelerometry jerk during sleep in children.

Weaver R Glenn, Chandrashekhar M V S, Armstrong Bridget, White Iii James W, Finnegan Olivia, Cepni Aliye B, Burkart Sarah, Beets Michael, Adams Elizabeth L, de Zambotti Massimiliano, Welk Gregory J, Nelakuditi Srihari, Brown Iii David, Pate Russ, Wang Yuan, Ghosal Rahul, Zhong Zifei, Yang Hongpeng

СтатьяПеревод в очереди

Аннотация

STUDY

OBJECTIVES

Evaluate wrist-placed accelerometry predicted heartrate compared to electrocardiogram (ECG) heartrate in children during sleep.

METHODS

Children (n = 82, 61% male, 43.9% black) wore a wrist-placed Apple Watch Series 7 (AWS7) and ActiGraph GT9X during a polysomnogram. Three-Axis accelerometry data was extracted from AWS7 and the GT9X. Accelerometry heartrate estimates were derived from jerk (the rate of acceleration change), computed using the peak magnitude frequency in short time Fourier Transforms of Hilbert transformed jerk computed from acceleration magnitude. Heartrates from ECG traces were estimated from R-R intervals using R-pulse detection. Lin's concordance correlation coefficient (CCC), mean absolute error (MAE), and mean absolute percent error (MAPE) assessed agreement with ECG estimated heart rate. Secondary analyses explored agreement by polysomnography sleep stage and a signal quality metric.

RESULTS

The developed scripts are available on Github. For the GT9X, CCC was poor at -0.11 and MAE and MAPE were high at 16.8 (SD = 14.2) beats/minute and 20.4% (SD = 18.5%). For AWS7, CCC was moderate at 0.61 while MAE and MAPE were lower at 6.4 (SD = 9.9) beats/minute and 7.3% (SD = 10.3%). Accelerometry estimated heartrate for AWS7 was more closely related to ECG heartrate during N2, N3 and REM sleep than lights on, wake, and N1 and when signal quality was high. These patterns were not evident for the GT9X.

CONCLUSIONS

Raw accelerometry data extracted from AWS7, but not the GT9X, can be used to estimate heartrate in children while they sleep. Future work is needed to explore the sources (i.e. hardware, software, etc.) of the GT9X's poor performance.

Для цитирования: Weaver R Glenn, Chandrashekhar M V S, Armstrong Bridget, White Iii James W, Finnegan Olivia, Cepni Aliye B, Burkart Sarah, Beets Michael, Adams Elizabeth L, de Zambotti Massimiliano, Welk Gregory J, Nelakuditi Srihari, Brown Iii David, Pate Russ, Wang Yuan, Ghosal Rahul, Zhong Zifei, Yang Hongpeng. Jerks are useful: extracting pulse rate from wrist-placed accelerometry jerk during sleep in children.. Sleep. 2025. DOI: 10.1093/sleep/zsae099.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.