Concurrent spinal and brain imaging with optically pumped magnetometers.

Mardell Lydia C, Spedden Meaghan E, O'Neill George C, Tierney Tim M, Timms Ryan C, Zich Catharina, Barnes Gareth R, Bestmann Sven

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The spinal cord and its interactions with the brain are fundamental for movement control and somatosensation. However, brain and spinal electrophysiology in humans have largely been treated as distinct enterprises, in part due to the relative inaccessibility of the spinal cord. Consequently, there is a dearth of knowledge on human spinal electrophysiology, including the multiple pathologies that affect the spinal cord as well as the brain.

NEW METHOD: Here we exploit recent advances in the development of wearable optically pumped magnetometers (OPMs) which can be flexibly arranged to provide coverage of both the spinal cord and the brain in relatively unconstrained environments. This system for magnetospinoencephalography (MSEG) measures both spinal and cortical signals simultaneously by employing custom-made scanning casts.

RESULTS

We evidence the utility of such a system by recording spinal and cortical evoked responses to median nerve stimulation at the wrist. MSEG revealed early (10 - 15 ms) and late (>20 ms) responses at the spinal cord, in addition to typical cortical evoked responses (i.e., N20).

COMPARISON WITH EXISTING

METHODS

Early spinal evoked responses detected were in line with conventional somatosensory evoked potential recordings.

CONCLUSION

This MSEG system demonstrates the novel ability for concurrent non-invasive millisecond imaging of brain and spinal cord.

Для цитирования: Mardell Lydia C, Spedden Meaghan E, O'Neill George C, Tierney Tim M, Timms Ryan C, Zich Catharina, Barnes Gareth R, Bestmann Sven. Concurrent spinal and brain imaging with optically pumped magnetometers.. Journal of neuroscience methods. 2024. DOI: 10.1016/j.jneumeth.2024.110131.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.