MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmbbm.2017.04.009

Медицинская библиотека · Journal of the mechanical behavior of biomedical materials · 2017

Stability of knee ligament complex of Thiel-embalmed cadaver compared to in vivo knee.

Völlner Florian, Pilsl Ulrike, Craiovan Benjamin, Zeman Florian, Schneider Michael, Wörner Michael, Grifka Joachim, Weber Markus

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

The first biomechanical evaluation of new implants is usually carried out with cadavers. Fixation of Thiel-embalmed cadavers is supposed to preserve the histological structure, colour and consistency of the tissue and has a low risk of infection and toxicity. However, the biomechanical properties of Thiel-fixated tissue are still unknown. The aim of this study was to quantify the effect of the Thiel-embalming method on the elastic properties of the ligament complex of the knee compared to in vivo knees during total knee arthroplasty.

METHODS

The results of biomechanical tensile tests with 10 Thiel-embalmed knees were compared with the findings of 10 patients who underwent total knee arthroplasty with a standardised knee balancer at our department. We reconstructed the force-elongation curves of the medial and lateral ligament complex and calculated the stiffness in direct correlation with overall soft tissue stability in full extension and in 90° of flexion.

RESULTS

All curves consisted of a non-linear part at the beginning and a linear part from about 80N onwards. In full extension, median stiffness in the cadavers was 26.6N/mm for the medial compartment and 31.6N/mm for the lateral compartment. The values for in vivo were 25.7N/mm for the medial compartment and 25.3N/mm for the lateral compartment (p=0.684 for the medial compartment and p=0.247 for the lateral compartment). In 90° of flexion, median stiffness in the cadaver group was 24.7N/mm for the medial compartment and 22.2N/mm for the lateral compartment. In vivo, median stiffness was 30.3N/mm for the medial compartment and 29.2N/mm for the lateral compartment (p=0.009 for the medial compartment and p=0.143 for the lateral compartment).

CONCLUSION

Stiffness of the medial and lateral ligament complex in the knee was comparable between Thiel-embalmed cadavers and in vivo patients during total knee arthroplasty. Thiel fixation seems to preserve the soft tissue properties similar to those in vivo.

Для цитирования: Völlner Florian, Pilsl Ulrike, Craiovan Benjamin, Zeman Florian, Schneider Michael, Wörner Michael, Grifka Joachim, Weber Markus. Stability of knee ligament complex of Thiel-embalmed cadaver compared to in vivo knee.. Journal of the mechanical behavior of biomedical materials. 2017. DOI: 10.1016/j.jmbbm.2017.04.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.