DOI 10.1097/bpo.0000000000002023
Retrograde Application of Humerus Fassier-Duval Rod in Osteogenesis Imperfecta: A New Surgical Technique.
Аннотация
BACKGROUND
The aim of this study is to describe the technique of retrograde application of Fassier-Duval (FD) rod for the humerus in patients with osteogenesis imperfecta (OI). This technique was developed to overcome the downsides of the previously used techniques of humerus rodding.
METHODS
The study was done at a tertiary care pediatric orthopaedic hospital from April 2014 to August 2021. Skeletally immature patients with OI who underwent retrograde FD rodding were included. This surgery was performed for humeral shaft fractures/bowing limited to the distal half of the bone to ensure appropriate stability of the fixation. Surgical technique of the procedure is described in detail.
RESULTS
Six patients with OI, of which 2 (33.3%) had FD rodding bilaterally, were included. The mean age at rodding was 7.6±3.5 (range: 3 to 14) years. The mean duration of postoperative follow-up was 45.5±18.0 (range: 24 to 75) months. All patients had full healing of the fracture/osteotomy, with functional alignment of their humeri. No surgical complications were observed; however, 1 (12.5%) segment only had a traumatic humerus fracture following a fall that was associated with rod migration, occurring 60 months postoperatively. This was treated with a retrograde FD rodding again, with fracture augmentation with plate and screws.
CONCLUSIONS
The retrograde FD rodding technique of the humerus in OI patients is relatively simple and preserves the soft tissue surrounding the shoulder joint, with favorable outcomes. Studies with larger sample size and long-term follow-up duration are needed.
LEVEL OF EVIDENCE: Level IV-case series.