MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1532-950x.2013.12048.x

Медицинская библиотека · Veterinary surgery : VS · 2013

Radiographic outcome and complications of tibial plateau leveling osteotomy stabilized with an anatomically contoured locking bone plate.

Kowaleski Michael P, Boudrieau Randy J, Beale Brian S, Piras Alessandro, Hulse Donald, Johnson Kenneth A

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the short-term clinical performance of an anatomically pre-contoured, locking plate in dogs undergoing tibial plateau leveling osteotomy (TPLO) for cranial cruciate ligament (CrCL) disease.

STUDY

DESIGN

Prospective, multi-center clinical study.

ANIMALS: Dogs (n = 56) undergoing TPLO.

METHODS

Signalment and operative data were recorded. Preoperative, postoperative, and follow-up tibial plateau angle (TPA) were measured from radiographic images. Intraoperative and postoperative complications were recorded; the latter were categorized as minor if additional surgery was not necessary, and major if surgery was needed to resolve the complication. Bone healing was scored and change in tibial plateau angle (TPACH ) between postoperative and follow up radiographic images was calculated.

RESULTS

Mean (± SD) preoperative TPA was 28.6 ± 3.8°, and mean postoperative TPA was 4.8 ± 1.9°. Four intraoperative complications (7.1%) including 2 cases of intra-articular screw placement, 3 minor postoperative complications (5.4%), and no major or catastrophic postoperative complications occurred. Median bone healing grade was 4/4 (excellent union >75% healing). Mean TPACH was 0.15 ± 1.32°.

CONCLUSIONS

Use of this anatomically contoured, locking TPLO plate by experienced surgeons is associated with accurate tibial plateau leveling, reliably excellent bone union at follow-up exam, minimal TPACH , and a lower complication rate than previously reported. Confining contouring to the distal shaft of the plate ensures there is precise apposition to the tibial diaphysis and mitigates the risk of intra-articular screw placement.

Для цитирования: Kowaleski Michael P, Boudrieau Randy J, Beale Brian S, Piras Alessandro, Hulse Donald, Johnson Kenneth A. Radiographic outcome and complications of tibial plateau leveling osteotomy stabilized with an anatomically contoured locking bone plate.. Veterinary surgery : VS. 2013. DOI: 10.1111/j.1532-950x.2013.12048.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.