MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/iae.0000000000000772

Медицинская библиотека · Retina (Philadelphia, Pa.) · 2016

OUTCOMES OF RETINAL DETACHMENT REPAIR AFTER POSTERIOR OPEN GLOBE INJURY.

Reed David C, Juhn Alexander T, Rayess Nadim, Hsu Jason, Chiang Allen

СтатьяПеревод в очереди

Аннотация

PURPOSE: To report outcomes of retinal detachment (RD) repair following posterior open globe injury.

METHODS

This retrospective, consecutive case series examined patients who underwent RD repair following Zone II and/or III open globe injury repair between January 1, 2007 and October 31, 2013. Patients with <3 months of follow-up since their last vitreoretinal surgery, and those who underwent pars plana vitrectomy (e.g., for intraocular foreign body) during their initial open globe injury repair were excluded.

RESULTS

Of 30 patients who met inclusion criteria, reattachment of the retina was achieved in 25 (83%) during the first vitreoretinal surgical procedure and 5 (17%) were deemed inoperable intraoperatively. Ten patients (30%) developed recurrent RD, and 8 underwent additional surgery. At last follow-up, reattachment was observed in 4 of these 8. The overall rate of final reattachment was 63% (19 patients). The mean number of surgeries for RD was 1.5 (range, 1-3). Fifteen patients (50%) achieved final visual acuity of counting fingers or better. Mean follow-up from the last vitreoretinal surgery was 23 months (range, 3-52).

CONCLUSION

Although RD following posterior open globe injury confers a grave prognosis, successful anatomic reattachment of the retina was achieved in the majority of patients in this series, with half achieving ambulatory vision.

Для цитирования: Reed David C, Juhn Alexander T, Rayess Nadim, Hsu Jason, Chiang Allen. OUTCOMES OF RETINAL DETACHMENT REPAIR AFTER POSTERIOR OPEN GLOBE INJURY.. Retina (Philadelphia, Pa.). 2016. DOI: 10.1097/iae.0000000000000772.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.