MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvir.2010.09.016

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2010

Influence of the secondary deployment of expanded polytetrafluoroethylene-covered stent grafts on maintenance of transjugular intrahepatic portosystemic shunt patency.

Jirkovsky Vaclav, Fejfar Tomas, Safka Vaclav, Hulek Petr, Krajina Antonin, Chovanec Vendelin, Raupach Jan, Lojik Miroslav, Vanasek Tomas, Renc Ondrej, Ali Shahzad M

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To evaluate the effects of secondary deployment of expanded polytetrafluoroethylene (ePTFE)-covered stent grafts in the treatment of dysfunctional transjugular intrahepatic portosystemic shunts (TIPSs) in comparison with other common approaches (conventional angioplasty or implantation of bare metal stents).

MATERIALS AND

METHODS

A retrospective review of 121 dysfunctional bare metal TIPS presenting between 2000 and 2004 was conducted. The group was divided into four subgroups according to the type of intervention: conventional angioplasty (52 cases; 43%), bare metal stent deployment (35 cases; 28.9%), nondedicated ePTFE-covered stent-graft deployment (15 cases; 12.4%), and dedicated ePTFE-covered stent-graft deployment (19 cases; 15.7%). In all four groups, the primary patency after the specific intervention was calculated and mutually compared.

RESULTS

Primary patency rates after 12 and 24 months were 49.7% and 25.3%, respectively, in conventional angioplasty; 74.9% and 64.9%, respectively, with bare metal stents; 75.2% and 64.5%, respectively, with nondedicated ePTFE-covered stent grafts; and 88.1% and 80.8%, respectively, with dedicated ePTFE-covered stent grafts.

CONCLUSIONS

In the treatment of dysfunctional TIPS, better patency after the intervention was obtained by deploying dedicated ePTFE-covered stent grafts in comparison with conventional angioplasty, bare metal stents, and nondedicated ePTFE-covered stents.

Для цитирования: Jirkovsky Vaclav, Fejfar Tomas, Safka Vaclav, Hulek Petr, Krajina Antonin, Chovanec Vendelin, Raupach Jan, Lojik Miroslav, Vanasek Tomas, Renc Ondrej, Ali Shahzad M. Influence of the secondary deployment of expanded polytetrafluoroethylene-covered stent grafts on maintenance of transjugular intrahepatic portosystemic shunt patency.. Journal of vascular and interventional radiology : JVIR. 2010. DOI: 10.1016/j.jvir.2010.09.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.