DOI 10.1016/j.apradiso.2013.02.021
Study of gamma ray response of R404A superheated droplet detector using a two-state model.
Аннотация
The superheated droplet detector (SDD) is known to be gamma ray insensitive below a threshold temperature which made them excellent candidates for neutron detection in the presence of gamma rays. Above the threshold temperature, the gamma ray detection efficiency increases with increase in temperature. In this work the gamma ray threshold temperature has been studied for SDD using R404A as the active liquid and is compared to the theoretical prediction. The temperature variation of gamma ray detection efficiency and interstate transition kinetics has also been studied using a two-state model. The experiments are performed at the ambient pressure of 1 atm and in the temperature range of 17-32 °C using a 662 keV (1)(37)Cs gamma ray source.