Медицинская библиотека · The Annals of pharmacotherapy · 2018

Anti-Xa Oral Anticoagulant Plasma Concentration Assay in Real Life: Rivaroxaban and Apixaban Quantification in Emergency With LMWH Calibrator.

Billoir Paul, Barbay Virginie, Joly Luc Marie, Fresel Marielle, Chrétien Marie Hélène, Le Cam Duchez Véronique

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Oral anti-Xa inhibitors have demonstrated noninferiority to vitamin K antagonists (VKAs) for the prevention of stroke in patients with atrial fibrillation and recurrent venous thromboembolism. They are associated with a decrease in major bleeding. In contrast with VKA, no coagulation monitoring is required. However, in clinical practice, determination of drug concentration is sometimes necessary.

OBJECTIVE

The objective of this study was to evaluate a low-molecular-weight heparin (LMWH) calibrated anti-Xa assay for the quantification of rivaroxaban and apixaban plasma concentration in emergency.

METHODS

The anti-Xa plasma concentration of rivaroxaban and apixaban were measured in emergency in 210 patients using STA anti-Xa liquid assay. For each plasma concentration <150 ng/mL of rivaroxaban or apixaban, an anti-Xa assay calibrated with LMWH was performed.

RESULTS

We demonstrated a significant correlation between LMWH anti-Xa activity and rivaroxaban ( R2 = 0.947) or apixaban ( R2 = 0.959) concentration and a significant correlation between rivaroxaban and apixaban plasma concentration ( R2 = 0.972). A LMWH anti-Xa activity <0.50 IU/mL could exclude a plasma concentration of rivaroxaban and apixaban >30 ng/mL and indicate the feasibility of invasive procedure. Conclusion and Relevance: In the absence of a specific test, LMWH-calibrated anti-Xa assay could be used to determine the presence and evaluate the plasma concentration of oral anti-Xa inhibitors. However, these initial findings require confirmation using other chromogenic calibrated oral anti-Xa assays.

Для цитирования: Billoir Paul, Barbay Virginie, Joly Luc Marie, Fresel Marielle, Chrétien Marie Hélène, Le Cam Duchez Véronique. Anti-Xa Oral Anticoagulant Plasma Concentration Assay in Real Life: Rivaroxaban and Apixaban Quantification in Emergency With LMWH Calibrator.. The Annals of pharmacotherapy. 2018. DOI: 10.1177/1060028018811657.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.