MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpeds.2025.114969

Медицинская библиотека · The Journal of pediatrics · 2025

Predicting Failure of Ventricular Shunts in the Emergency Department: The SMaRT (Shunt Malfunction and Revision Triage) Score.

Lehner Kurt R, Kalluri Anita L, Jiang Kelly, Alawneh Rama J, Lee Ryan P, Kazemi Foad, Yea Joan, Chandan Reddy Sai, Shaw Jacob, Kane Ann, Jackson Eric M

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To create a simple scoring system to stratify likelihood of shunt failure in the emergency department.

STUDY

DESIGN

We conducted a retrospective cohort study of all children presenting to the pediatric emergency department with concern for ventricular shunt failure from 2017 to 2022. A separate dataset from 2022 to 2023 was used for validation. The main predictors of shunt revision were determined using univariate and multivariable regression models, and a scoring system utilizing the top predictors of ventricular shunt malfunction was created.

RESULTS

There were 1167 neurosurgical consultations for shunt malfunction during the study period which resulted in 285 shunt revisions. Utilizing the 10 variables most associated with revision (increased ventricle size, abnormal shunt series, bradycardia, lethargy, altered mental status, vomiting, headache, shorter time interval from last shunt surgery, seizure, and the presence of upper respiratory symptoms), a SMaRT score was developed. For Shunt Malfunction and Revision Triage (SMaRT) score <4, we achieved a receiver-operating characteristic area under the curve of 0.87 with sensitivity of 0.93, specificity of 0.58, positive predictive value of 0.42, and negative predictive value of 0.96. This was confirmed in a separate validation set of 119 patients. A similar analysis excluding imaging data yielded a significant decrease in the discrimination of the scoring system, dropping the receiver-operating characteristic area under the curve to 0.71.

CONCLUSIONS

The SMaRT score provides a data-driven tool to determine the utility of a neurosurgical consult for shunt malfunction with a high negative predictive value for shunt malfunction in its lowest tier. Use of this tool has the potential to improve triage and resource utilization in the emergency department.

Для цитирования: Lehner Kurt R, Kalluri Anita L, Jiang Kelly, Alawneh Rama J, Lee Ryan P, Kazemi Foad, Yea Joan, Chandan Reddy Sai, Shaw Jacob, Kane Ann, Jackson Eric M. Predicting Failure of Ventricular Shunts in the Emergency Department: The SMaRT (Shunt Malfunction and Revision Triage) Score.. The Journal of pediatrics. 2025. DOI: 10.1016/j.jpeds.2025.114969.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.