MedElevator Войти в исследования
← Поиск публикаций

DOI 10.17712/nsj.2021.1.20200040

Медицинская библиотека · AJNR. American journal of neuroradiology · 2005

Evaluation of platybasia with MR imaging.

Koenigsberg Robert A, Vakil Nakul, Hong Tom A, Htaik Tun, Faerber Eric, Maiorano Tina, Dua Monica, Faro Scott, Gonzales Carlos

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Platybasia, or abnormal obtuseness of the basal angle, was first measured on plain skull images. At present, evaluation of the brain and skull more commonly involves CT and MR imaging. We evaluated a new MR imaging method of evaluating platybasia.

METHODS

We retrospectively evaluated midline sagittal MR images in 200 adults and 50 children. The basal angle of the skull base was measured by using two methods: The standard MR imaging technique measured the angle formed by two lines-one joining the nasion and the center of the pituitary fossa connected by a line joining the anterior border of the foramen magnum and center of the pituitary fossa. The modified technique measured the angle formed by a line across the anterior cranial fossa and dorsum sellae connecting a line along the clivus.

RESULTS

With the standard MR imaging technique, we obtained mean angles of 129 degrees +/- 6 degrees for adults and 127 degrees +/- 5 degrees for children, compared with 135.3 degrees (composite mean) in previous series. The modified technique produced values of 117 degrees +/- 6 degrees for adults and 114 degrees +/- 5 degrees for children, which were significantly lower that those of standard MR imaging and traditional radiography (P <.05).

CONCLUSION

Both the standard and modified MR imaging techniques produced basal angles lower than those previously reported with standard radiography. The modified technique uses clearly featured landmarks that can be reproduced consistently on midline sagittal T1 images. This technique and its corresponding values can be used as the new standard for evaluating the basal angle.

Для цитирования: Koenigsberg Robert A, Vakil Nakul, Hong Tom A, Htaik Tun, Faerber Eric, Maiorano Tina, Dua Monica, Faro Scott, Gonzales Carlos. Evaluation of platybasia with MR imaging.. AJNR. American journal of neuroradiology. 2005. DOI: 10.17712/nsj.2021.1.20200040.