MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00247-020-04771-5

Медицинская библиотека · Pediatric radiology · 2020

Outpacing movement - ultrafast volume coverage in neuropediatric magnetic resonance imaging.

Gräfe Daniel, Roth Christian, Weisser Margit, Krause Matthias, Frahm Jens, Voit Dirk, Hirsch Franz Wolfgang

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Conventional MRI sequences are often affected in neuropediatric imaging by unavoidable movements. Therefore, children younger than 6 years usually have to be examined under sedation/anesthesia. A new real-time MRI technique with automatic slice advancement allows for motion-robust T2-weighted volume coverage of the whole brain within a few seconds in adults.

OBJECTIVE

To evaluate to which extent the new volume coverage method can be used to visualize cerebrospinal fluid and reduce the need for anesthesia in children.

MATERIALS AND

METHODS

We assessed 30 children ages 6 years and younger with suspected or proven hydrocephalus, hygroma or macrocephalus using volume coverage sequences with 20 slices per second in three planes. If necessary, a parent was placed in the bore together with the child for calming and gentle immobilization. We compared visualization of cerebrospinal fluid spaces and course of the shunt catheter in volume coverage sequences vs. fast spin-echo sequences.

RESULTS

The clinical issue could be sufficiently assessed in all children with use of volume coverage sequences, whereas conventional fast spin-echo sequences performed moderately to poorly. Visualization of the tip of a shunt failed in 16% of volume coverage scans and 27% of turbo spin-echo scans. A subsequent examination under anesthesia was never necessary. None of the examinations had to be stopped prematurely.

CONCLUSION

The motion-robust volume coverage sequences with T2-type contrast can be used to avoid sedation of children in the evaluation of cerebrospinal fluid spaces, even in the presence of vigorous motion. For other indications and contrasts, the technique must still be evaluated.

Для цитирования: Gräfe Daniel, Roth Christian, Weisser Margit, Krause Matthias, Frahm Jens, Voit Dirk, Hirsch Franz Wolfgang. Outpacing movement - ultrafast volume coverage in neuropediatric magnetic resonance imaging.. Pediatric radiology. 2020. DOI: 10.1007/s00247-020-04771-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.