Laparoscopy-assisted intrapelvic sonography with a high-frequency, real-time miniature transducer for assessment of the Fallopian tube: a preliminary report.

Senoh D, Yanagihara T, Akiyama M, Ohnishi Y, Yamashiro C, Tanaka H, Hayashi K, Hata T

СтатьяПеревод в очереди

Аннотация

Our purpose was to visualize normal and abnormal Fallopian tubes using laparoscopy-assisted intrapelvic sonography with a specially developed 20 MHz flexible catheter-based high-resolution, real-time miniature (2.4 mm outer diameter) ultrasound transducer in infertile women. A total of 21 women (20 infertile, one with unilateral hydrosalpinx, and one tubal pregnancy) were studied with pelvic saline effusion under laparoscopy. Fimbriae were clearly depicted with a cockscomb-like form in 95% of patients. All ampullae were visualized, and mucosal layers were clearly distinguished from muscle layers in 70% of patients. Scanty intratubal effusion was noted in 50% of patients, and tubal spastic findings were found in 10% of patients. In all, 60% of isthmuses were detected, and mucosal layers were distinguished from muscle layers in 30%. In the subject with hydrosalpinx, the tubal wall was thinner, and it was not possible to distinguish between muscle and mucosal layers. In the subject with a tubal pregnancy, the amniotic membrane and decidua were depicted more clearly than by transvaginal sonography. In conclusion, laparoscopy-assisted intrapelvic sonography with a high-frequency, real-time miniature transducer may be useful in the assessment of tubal texture and function in tubal disorders, possibly in infertility practice.

Для цитирования: Senoh D, Yanagihara T, Akiyama M, Ohnishi Y, Yamashiro C, Tanaka H, Hayashi K, Hata T. Laparoscopy-assisted intrapelvic sonography with a high-frequency, real-time miniature transducer for assessment of the Fallopian tube: a preliminary report.. Human reproduction (Oxford, England). 1999. DOI: 10.1093/humrep/14.3.704.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.