DOI 10.1016/j.wneu.2017.03.015
Low-Cost Smartphone-Based Photogrammetry for the Analysis of Cranial Deformation in Infants.
Аннотация
BACKGROUND
Cranial deformation, including deformational plagiocephaly, brachycephaly, and craniosynostosis, is a condition that affects a large number of infants. Despite its prevalence, there are no standards for the systematic evaluation of the cranial deformation. Usually, the deformation is measured manually by the use of calipers. Experts, however, do not agree on the suitability of these measurements to correctly represent the deformation. Other methodologies for evaluation include 3-dimensional (3D) photography and radiologic scanners. These techniques require either patient's sedation and ionizing radiation or high investment. The aim of this study is to develop a novel, low-cost, and minimally invasive methodology to correctly evaluate the cranial deformation using 3D imagery.
METHODS
A smart phone was used to record a slow motion video sequence on 5 different patients. Then, the videos were processed to create accurate 3D models of the patients' head, and the results were compared with the measurements obtained by the manual caliper.
RESULTS
The correspondence between the manual and the photogrammetric 3D model measurements was high as far as head marks are available, with differences of 2 mm ± 0.9 mm; without marks, measurement results differed up to 20 mm.
CONCLUSIONS
Smartphone-based photogrammetry is a low-cost, highly useful methodology to evaluate cranial deformation. This technique provides a much larger quantity of information than linear measurements with a similar accuracy as far as head marks exist. In addition, a new approach for the evaluation is pointed out: the comparison between the head 3D model and an ideal head, represented by a 3-axis ellipsoid.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.