MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/jcma.0000000000000524

Медицинская библиотека · Journal of the Chinese Medical Association : JCMA · 2021

Transthoracic echocardiography monitoring during atrial septal defect and ventricular septal defect device closures using a three-dimensional printed transducer holder.

Jian Wen-Yen, Lin Su-Man, Tsai Shen-Kou, Hwang Betau

СтатьяПеревод в очереди

Аннотация

Transthoracic echocardiography (TTE) is noninvasive but can only be performed intermittently during fluoroscopy. In a prior study, we created a transducer holder device to allow for hemodynamic monitoring in the intensive care unit. The current study is the first instance of the use of a three-dimensional (3D)-printed TTE transducer holder, which is easily customized and personalized to a previous transducer holder at relatively low cost and short production time, to enable continuous TTE monitoring during device closure of an atrial septal defect (ASD) and ventricular septal defect (VSD). There were 14 ASD patients and 9 VSD patients scheduled to undergo device closure. The study's real-time TTE monitoring was performed by using a 3D-printed transducer holder over the course of the entire implantation procedure. There were 23 patients who successfully underwent septal closures using the 3D-printed holder that enabled real-time images over the entire procedure. The median duration for real-time TTE guidance was 15 minutes for the ASD and 36 minutes for the VSD and the median fluoroscopy time was 11 minutes for the ASD and 30 minutes for the VSD. One migrating VSD occluder and one case of aortic regurgitation after occluder deployment were noted by real-time TTE monitoring during the procedure. Our novel 3D-printed transducer holder can provide transesophageal echocardiography-like real-time imaging during device closure of an ASD and a VSD and may become a new alternative method in ASD and VSD closures. It can also prevent radiation exposure for the intervention team who would otherwise need to perform TTE during live fluoroscopy.

Для цитирования: Jian Wen-Yen, Lin Su-Man, Tsai Shen-Kou, Hwang Betau. Transthoracic echocardiography monitoring during atrial septal defect and ventricular septal defect device closures using a three-dimensional printed transducer holder.. Journal of the Chinese Medical Association : JCMA. 2021. DOI: 10.1097/jcma.0000000000000524.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.