OBJECTIVES

To determine the proportion of patients requiring secondary surgery for symptomatic implant removal after open reduction, internal fixation using dual mini-fragment plating technique for clavicular shaft fractures.

DESIGN

Retrospective observational study.

SETTING

Single university Level 1 trauma center.

PATIENTS: Eighty-one patients treated with open reduction, internal fixation using dual mini-fragment plating technique for clavicular shaft fractures (OTA/AO 15-B1, B2, and B3) with minimum 12-month follow-up (median 477 days; range 371-1549 days).

INTERVENTION: Open reduction, internal fixation using dual mini-fragment plating technique for clavicular shaft fractures.

MAIN OUTCOME MEASUREMENTS: Incidence of secondary surgery, QuickDASH (Disabilities of the Arm, Shoulder, and Hand) scores.

RESULTS

Six of 81 patients (7.4%) underwent secondary surgery for implant removal for any reason. Of these, 3 (3.7%) underwent symptomatic implant (soft-tissue irritation) removal, 2 (2.5%) required implant removal in the setting of infection, and 1 patient (1.2%) required revision open reduction internal fixation for early implant failure. The mean QuickDASH score in this series was 8.44 (±6.94, range 0-77.27). The associated implant cost of the typical construct utilized in this series was $1511.38. The mean surgical time was 97 minutes (range 71-143 minutes).

CONCLUSIONS

The utilization of a dual mini-fragment plating technique in the treatment of clavicular shaft fractures results in a low rates of secondary surgery for symptomatic implant removal (3.7%) and similar QuickDASH scores when compared with historical controls treated with 3.5-mm plates placed on the superior clavicle. Potential disadvantages in using this technique include a higher surgical implant cost and length of surgery.

LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Для цитирования: Czajka Cory M, Kay Andrew, Gary Joshua L, Prasarn Mark L, Choo Andrew M, Munz John W, Harvin William H, Achor Timothy S. Symptomatic Implant Removal Following Dual Mini-Fragment Plating for Clavicular Shaft Fractures.. Journal of orthopaedic trauma. 2017. DOI: 10.1097/bot.0000000000000760.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.