MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00062-023-01313-y

Медицинская библиотека · Clinical neuroradiology · 2023

Nidus Compacity Determined by Semi-Automated Segmentation is a Strong Quantitative Predictor of Brain Arterio-Venous Malformation Cure.

Pacini Aurélien, Shotar Eimad, Granger Benjamin, Maizeroi-Eugène Franck, Delaitre Mariette, Talbi Atika, Boch Anne-Laure, Valéry Charles-Ambroise, Premat Kévin, Drir Mehdi, Lenck Stéphanie, Mounayer Charbel, Sourour Nader-Antoine, Clarençon Frédéric

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVE

A compact nidus is a well-known feature of good outcome after treatment in brain arteriovenous malformations (bAVM). This item, included in the "Supplementary AVM grading system" by Lawton, is subjectively evaluated on DSA. The present study aimed to assess whether quantitative nidus compacity along with other angio-architectural bAVM features were predictive of angiographic cure or the occurrence of procedure-related complications.

MATERIALS AND

METHODS

Retrospective analysis of 83 patients prospectively collected data base between 2003 to 2018 having underwent digital subtraction 3D rotation angiography (3D-RA) for pre-therapeutic assessment of bAVM. Angio-architectural features were analyzed. Nidus compacity was measured with a dedicated segmentation tool. Univariate and multivariate analyses were performed to test the association between these factors and complete obliteration or complication.

RESULTS

Compacity was the only significant factor associated with complete obliteration in our predictive model using logistic multivariate regression; the area under the curve for compacity predicting complete obliteration was excellent (0.82; 95% CI 0.71-0.90; p < 0.0001). The threshold value maximizing the Youden index was a compacity > 23% (sensitivity 97%; specificity 52%; 95% CI 85.1-99.9; p = 0.055). No angio-architectural factor was associated with the occurrence of a complication.

CONCLUSION

Nidus high compacity quantitatively measured on 3D-RA, using a dedicated segmentation tool is predictive of bAVM cure. Further investigation and prospective studies are warranted to confirm these preliminary results.

Для цитирования: Pacini Aurélien, Shotar Eimad, Granger Benjamin, Maizeroi-Eugène Franck, Delaitre Mariette, Talbi Atika, Boch Anne-Laure, Valéry Charles-Ambroise, Premat Kévin, Drir Mehdi, Lenck Stéphanie, Mounayer Charbel, Sourour Nader-Antoine, Clarençon Frédéric. Nidus Compacity Determined by Semi-Automated Segmentation is a Strong Quantitative Predictor of Brain Arterio-Venous Malformation Cure.. Clinical neuroradiology. 2023. DOI: 10.1007/s00062-023-01313-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.