MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/00368504251386310

Медицинская библиотека · Science progress · 2025

Construction and validation of a risk prediction model for intraoperative hypothermia in children undergoing thoracoscopic lobectomy.

Liu Xiongtao, Lin Hua, Li Yanzhen, Dong Chunli, Wang Ting, Wang Xia, Yan Qiqi, Liu Ruzhong, Zhao Liyan, Xiao Juan, Gou Xiaohui

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

To develop a predictive model to assess the risk of peri-operative hypothermia occurrence in children undergoing thoracoscopic lobectomy and validate its effectiveness. 172 children who underwent thoracoscopic lobectomy were randomly divided into a training set of 124 cases and a validation set of 48 cases in a 7:3 ratio. The study found a 33.1% incidence of intraoperative hypothermia (IPH) in children undergoing thoracoscopic lobectomy. Logistic regression analysis was performed using SPSS 26.0 to screen influencing factors, establish a risk prediction model, and draw the receiver-operating characteristic curve. Univariate analysis identified anesthesia-skin incision time, operating-room temperature, humidity, basal body temperature, end body temperature, and body temperature half an hour after anesthesia as influencing factors. Multivariate logistic regression revealed anesthesia-skin incision time (odds ratio (OR) = 1.595), operating-room humidity (OR = 4.094), and body temperature half an hour after anesthesia (OR = 112.595) as independent predictors. The nomogram model demonstrated an excellent discrimination with area under the curve (AUC) of 0.989 (95% confidence interval (CI): 0.976-1.000), maximum Youden index of 0.94, sensitivity of 1, specificity of 0.94, and cutoff value of 0.195. The Hosmer-Lemeshow test (χ2 = 1.751, P = 0.195) and bootstrap resampling (consistency coefficient = 0.947) confirmed the model's goodness of fit, internal consistency, and stability. Validation set results are similar to those in the training set, with an AUC of 0.989 (95% CI: 0.969-1.000), a sensitivity of 1, a specificity of 0.929, and a calibration curve error of 0.032 (<0.05), indicating high predictive accuracy. These findings suggest nomogram is a robust tool for predicting IPH in the pediatric thoracoscopic lobectomy.

Для цитирования: Liu Xiongtao, Lin Hua, Li Yanzhen, Dong Chunli, Wang Ting, Wang Xia, Yan Qiqi, Liu Ruzhong, Zhao Liyan, Xiao Juan, Gou Xiaohui. Construction and validation of a risk prediction model for intraoperative hypothermia in children undergoing thoracoscopic lobectomy.. Science progress. 2025. DOI: 10.1177/00368504251386310.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.