Ocular abnormalities and systemic disease in Down syndrome.

Stirn Kranjc Branka

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Ocular problems as refractive errors, strabismus, accommodation, and cataract are well known in children with Down syndrome (DS). However, there is little information on the possible correlation of eye problems with systemic diseases such as heart defect (with or without surgery), hypotony, hypothyroidism, hearing loss, and others.

METHODS

Ophthalmic problems versus certain systemic diseases were studied in 65 children with DS, aged 2 months to 13 years, referred to the University Eye Hospital Ljubljana, Slovenia from 2008 to 2010. Standard ophthalmic examination methods were used, and physical data were taken from pediatric records.

RESULTS

Ocular findings included nystagmus (29.2%), esotropia (26.1%), epiphora (21.5%), Brushfield spots (16.9%), lens opacities (12.3%), abnormalities of the retinal vessels, foveal hypoplasia, or retinal pigment epithelium hyperplasia (32.2%), and optic disc pallor (7.6%). Hyperopia (36.9%) was the most frequent refractive error in the group, followed by astigmatism (29.2%) and myopia (24.6%). No diagnosed systemic abnormalities were found in 18.3% of the children, while 30.7% had congenital heart defect. Hypothyroidism, hypotony, hearing loss, gastrointestinal tract malformations, and leukemia were less common. Nystagmus was related to myopia and esotropia, and to heart disease and heart operations.

CONCLUSIONS

Comorbidities are common in DS and complicate diagnosis, development, and therapy.

Для цитирования: Stirn Kranjc Branka. Ocular abnormalities and systemic disease in Down syndrome.. Strabismus. 2012. DOI: 10.3109/09273972.2012.680234.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.