MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0271678x16668891

Медицинская библиотека · Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism · 2016

Comparison of two PET radioligands, [11C]FPEB and [11C]SP203, for quantification of metabotropic glutamate receptor 5 in human brain.

Lohith Talakad G, Tsujikawa Tetsuya, Siméon Fabrice G, Veronese Mattia, Zoghbi Sami S, Lyoo Chul Hyoung, Kimura Yasuyuki, Morse Cheryl L, Pike Victor W, Fujita Masahiro, Innis Robert B

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

Of the two 18F-labeled PET ligands currently available to image metabotropic glutamate receptor 5 (mGluR5), [18F]FPEB is reportedly superior because [18F]SP203 undergoes glutathionlyation, generating [18F]-fluoride ion that accumulates in brain and skull. To allow multiple PET studies on the same day with lower radiation exposure, we prepared [11C]FPEB and [11C]SP203 from [11C]hydrogen cyanide and compared their abilities to accurately quantify mGluR5 in human brain, especially as regards radiometabolite accumulation. Genomic plot was used to estimate the ratio of specific-to-nondisplaceable uptake ( BPND) without using a receptor blocking drug. Both tracers quantified mGluR5; however [11C]SP203, like [18F]SP203, had radiometabolite accumulation in brain, as evidenced by increased distribution volume ( VT) over the scan period. Absolute VT values were ∼30% lower for 11C-labeled compared with 18F-labeled radioligands, likely caused by the lower specific activities (and high receptor occupancies) of the 11C radioligands. The genomic plot indicated ∼60% specific binding in cerebellum, which makes it inappropriate as a reference region. Whole-body scans performed in healthy subjects demonstrated a low radiation burden typical for 11C-ligands. Thus, the evidence suggests that [11C]FPEB is superior to [11C]SP203. If prepared in higher specific activity, [11C]FPEB would presumably be as effective as [18F]FPEB for quantifying mGluR5 in human brain.

Для цитирования: Lohith Talakad G, Tsujikawa Tetsuya, Siméon Fabrice G, Veronese Mattia, Zoghbi Sami S, Lyoo Chul Hyoung, Kimura Yasuyuki, Morse Cheryl L, Pike Victor W, Fujita Masahiro, Innis Robert B. Comparison of two PET radioligands, [11C]FPEB and [11C]SP203, for quantification of metabotropic glutamate receptor 5 in human brain.. Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism. 2016. DOI: 10.1177/0271678x16668891.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.