Rhythm and conduction disturbances in isolated, congenitally corrected transposition of the great arteries.

Daliento L, Corrado D, Buja G, John N, Nava A, Thiene G

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The incidence and types of rhythm and conduction disturbances in 11 male and 6 female patients with congenitally corrected transposition of the great arteries and no other intrinsic complicating anomalies were studied. Patient age ranged from 5 to 54 years; follow-up ranged from 5 to 37 years. Surface electrocardiograms were recorded in each patient; 15 also underwent 24-hour Holter monitoring and 10 underwent electrophysiologic study. The conduction system of a 54-year-old woman who died suddenly, with complete atrioventricular (AV) block since age 30 years, was studied by serial histologic sections. Fifteen patients were asymptomatic and 2 reported repeated episodes of palpitation since childhood. Ten patients presented with a normal PR interval and 2 with first-degree AV block (12%). Five patients had complete AV block (29%), but none had had it at birth; first- and second-degree AV block preceded complete AV block in 2 patients. The morphologic pattern and duration of QRS suggested a junctional rhythm in 4 patients and an idioventricular pacemaker in 1 patient. Electrophysiologic studies confirmed that the complete AV block site was supra-Hisian in 2 patients and proximal to the His bundle bifurcation in 1 patient. However, histologic investigation disclosed fibrosis and disruption of the proximal nonbifurcating His bundle in the patient who died suddenly. In 2 patients with recurrent supraventricular tachycardia, electrophysiologic studies suggested reentry through James fibers (or dual AV nodal pathway) in 1 and the presence of a left lateral accessory AV pathway in the other. Holter monitoring showed a high incidence of ventricular arrhythmias.

Для цитирования: Daliento L, Corrado D, Buja G, John N, Nava A, Thiene G. Rhythm and conduction disturbances in isolated, congenitally corrected transposition of the great arteries.. The American journal of cardiology. 1986. DOI: 10.1016/0002-9149(86)90069-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.