m+Medelevator.RU
← Поиск публикаций
Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2018

Safe Intraoperative Neurophysiologic Monitoring During Posterior Spinal Fusion in a Patient With Cochlear Implants.

Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Abiola Godwin, Ward Bryan Kevin, Bowditch Stephen, Ritzl Eva Katharina, Carey John Patrick

Аннотация

OBJECTIVE: Cochlear implants are generally considered a contraindication for any procedure requiring electrical stimulation near the implant. We present a case of a patient undergoing intraoperative transcranial electrical motor-evoked potential monitoring with a cochlear implant without adverse outcomes.

PATIENT: A 12-year-old girl with a history of VACTERL presented with worsening congenital kyphosis and bilateral severe-to-profound hearing loss. Since age 7 the patient used a cochlear implant in the right ear and hearing aid in the left ear. Physical examination and magnetic resonance imaging in 2016 revealed a left-sided 66-degree thoracolumbar kyphosis at T11 making the patient a candidate for surgical correction.

INTERVENTIONS: She underwent a posterior spinal fusion surgery, performed with intraoperative transcranial electrical motor-evoked potential monitoring. Steps were taken to mitigate electrical stimulation of the patient's cochlear implant.

MAIN OUTCOME MEASURES: Postoperative impedance of individual channels, audiometry, and neural response testing were compared with preoperative measurements.

RESULTS: Significant (>10%) impedance changes were observed postoperatively in channels 1, 2, 4, and 6; however, the net variation across all the channels was low (3%). The patient reported no hearing changes, and no significant changes in hearing threshold were seen in postoperative audiometric testing or neural response testing.

CONCLUSION: We present a case of successful posterior spinal fusion with intraoperative neurophysiological monitoring via transcranial electrical stimulation, in a patient with a cochlear implant. With proper precautions, motor-evoked potential monitoring can be safely performed in a patient with a cochlear implant.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты