Медицинская библиотека · Acta oto-laryngologica · 2016

The diagnostic value of measurement of cochlear length and height in temporal bone CT multiplanar reconstruction of inner ear malformation.

Liu Yi-Kang, Qi Cheng-Lin, Tang Jie, Jiang Mu-Liang, Du Long, Li Zhen-Hua, Tan Song-Hua, Tang An-Zhou

СтатьяПеревод в очереди

Аннотация

CONCLUSION

The cochlear length (CL) and cochlear height (CH) measured through MPR will provide for more accurate quantitative diagnosis of inner ear malformation, and are subsequently convenient for calculating cochlear duct length (CDL) before cochear implant.

OBJECTIVES

Qualitative and quantitative diagnosis of inner ear malformation in deaf patients through multiplanar reconstruction (MPR) was performed to provide a reference for cochlear implants.

METHODS

One hundred and two cases without sensorineural deafness and 560 patients with sensorineural deafness had MPR of temporal bone computed tomography performed to obtain the standardized cochlear-view and oblique coronal-view images. The inner ear radial lines were measured to formulate normal values for inner ear malformation diagnosing, and the CDL was estimated based on CL.

RESULTS

The normal range values of inner ear radial lines were measured and formulated, of which CL was 8.1-9.59 mm and CH was 3.28-3.90 mm. According to inner ear morphology and the normal values measured above, 61 cases of incomplete partition-type II (IP-II) and a high percentage (27/110, 24.5%) of hypoplasia of cochlea (HC) were diagnosed. The HC group was further divided into 1-turn, 1.5-turn, and 2-turn sub-groups, which had CDL of 15.98 ± 1.48 mm, 21.36 ± 0.96 mm, and 26.56 ± 0.60 mm, respectively.

Для цитирования: Liu Yi-Kang, Qi Cheng-Lin, Tang Jie, Jiang Mu-Liang, Du Long, Li Zhen-Hua, Tan Song-Hua, Tang An-Zhou. The diagnostic value of measurement of cochlear length and height in temporal bone CT multiplanar reconstruction of inner ear malformation.. Acta oto-laryngologica. 2016. DOI: 10.1080/00016489.2016.1221132.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.