Visual liver assessment using Gd-EOB-DTPA-enhanced magnetic resonance imaging of patients in the early post-Fontan period.

Nakajima Kimiko, Seki Mitsuru, Hatakeyama Shinitsu, Arai Shuhei, Asami Yuji, Tanaka Kensuke, Ikeda Kentaro, Shimoyama Shinya, Kobayashi Tomio, Miyamoto Takashi, Okada Yasunori, Arakawa Hirokazu, Takizawa Takumi

СтатьяПеревод в очереди

Аннотация

No imaging modality can be used to evaluate Fontan-associated liver disease (FALD). We retrospectively reviewed hepatic gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced magnetic resonance imaging (EOB-MRI) characteristics of patients within 1 year post-Fontan procedure, and we evaluated the association between hepatic imaging abnormalities and clinical parameters, including follow-up cardiac catheterization and laboratory test findings. The EOB-MR images were graded, based on the extent of the decreased enhancement, as "normal" (Grade 1), "segmental" (Grade 2), "regional" (Grade 3), and "diffuse" (Grade 4). We enrolled 37 patients (mean age, 3.5 ± 1.0 years): 9 patients had Grade 1 or 2; 14 patients, Grade 3; and 14 patients, Grade 4. EOB-MRI revealed characteristic reticular or mosaic patterns of diminished enhancement (i.e. "frog spawn" appearance). Ultrasonography did not detect diminished enhancement or "frog spawn" appearance. A trend existed toward increased grade severity in imaging with increased central venous pressure, pulmonary vascular resistance, and gamma-glutamyltransferase levels. Noninvasive EOB-MRI revealed the characteristic pattern of diminished enhancement, which was correlated with certain clinical parameters indicative of Fontan physiology and liver dysfunction. Early-stage FALD may occur soon after the Fontan procedure and is associated with increased pressure in the inferior vena cava and hepatic veins.

Для цитирования: Nakajima Kimiko, Seki Mitsuru, Hatakeyama Shinitsu, Arai Shuhei, Asami Yuji, Tanaka Kensuke, Ikeda Kentaro, Shimoyama Shinya, Kobayashi Tomio, Miyamoto Takashi, Okada Yasunori, Arakawa Hirokazu, Takizawa Takumi. Visual liver assessment using Gd-EOB-DTPA-enhanced magnetic resonance imaging of patients in the early post-Fontan period.. Scientific reports. 2020. DOI: 10.1038/s41598-020-61618-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.