MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s1076-6332(96)80002-x

Медицинская библиотека · Academic radiology · 1996

Magnetic resonance imaging of normal meningeal enhancement at 1.5 T.

Quint D J, Eldevik O P, Cohen J K

СтатьяПеревод в очереди

Аннотация

RATIONALE AND

OBJECTIVES

We examined patterns of intracranial meningeal enhancement on gadolinium chelate contrast media-enhanced 1.5-T spin-echo magnetic resonance (MR) imaging and developed criteria that might be useful for distinguishing between normal and abnormal meningeal enhancement.

METHODS

The convexity, falx cerebri, tentorium cerebelli, and suprasellar cistern regions of 204 patients were prospectively evaluated for contrast enhancement with a grading system ranging from 0 (no enhancement) to 5 (diffuse, irregular, thickened enhancement). Meningeal findings were correlated with other MR abnormalities and pertinent clinical histories that have been associated previously with meningeal enhancement.

RESULTS

Short-segment convexity meningeal enhancement was commonly seen and most likely represents intravascular contrast material in normal meningeal vessels. Such enhancement did not correlate with the presence of other MR abnormalities. Long-segment (> 3 cm) or diffuse convexity meningeal enhancement did correlate with other significant MR abnormalities and pertinent clinical history. Fine linear falcine and tentorial meningeal enhancement, as an isolated finding, did not correlate with other MR or clinical abnormalities. The suprasellar cistern and ventricular walls were rarely enhanced.

CONCLUSION

Short-segment convexity meningeal contrast enhancement is a normal finding representing normal vascular structures. More extensive convexity meningeal enhancement is abnormal and should prompt careful examination of the remainder of an MR image as well as the patient's clinical history for an etiology of the enhancement.

Для цитирования: Quint D J, Eldevik O P, Cohen J K. Magnetic resonance imaging of normal meningeal enhancement at 1.5 T.. Academic radiology. 1996. DOI: 10.1016/s1076-6332(96)80002-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.