This revision to the EEG Guidelines is an update incorporating the current electroencephalography technology and practice. It was previously published as Guideline 2. Similar to the prior guideline, it delineates the aspects of Guideline 1 that should be modified for neonates and young children. Recording conditions for photic stimulation and hyperventilation are revised to enhance the provocation of epileptiform discharges. Revisions recognize the difficulties involved in performing an EEG under sedation in young children. Recommended neonatal EEG montages are displayed for the reduced set of electrodes only since the montages in Guideline 3 should be used for a 21-electrode 10-20 system array. Neonatal documentation is updated to use current American Academy of Pediatrics term "postmenstrual age" rather than "conceptional age." Finally, because therapeutic hypothermia alters the prognostic value of neonatal EEG, the necessity of documenting the patient's temperature at the time of recording is emphasized.

Для цитирования: Kuratani John, Pearl Phillip L, Sullivan Lucy, Riel-Romero Rosario Maria S, Cheek Janna, Stecker Mark, San-Juan Daniel, Selioutski Olga, Sinha Saurabh R, Drislane Frank W, Tsuchida Tammy N. American Clinical Neurophysiology Society Guideline 5: Minimum Technical Standards for Pediatric Electroencephalography.. Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society. 2016. DOI: 10.1097/wnp.0000000000000321.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.