MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1378/chest.114.1.150

Медицинская библиотека · Chest · 1998

Investigation of pleural effusion: an evaluation of the new Olympus LTF semiflexible thoracofiberscope and comparison with Abram's needle biopsy.

McLean A N, Bicknell S R, McAlpine L G, Peacock A J

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

STUDY

OBJECTIVES

Recently, pulmonologists have performed thoracoscopy under local anesthesia using rigid thoracoscopes or flexible bronchoscopes. The latter allow greater access within the pleural cavity but are difficult to manipulate. The Olympus LTF semiflexible fiberoptic thoracoscope combines features of both instruments, having a solid body and a flexible terminal section. In the first study with this instrument, we evaluated ease of use and compared diagnostic yield with closed needle biopsy.

PATIENTS: Twenty-four patients with pleural effusion were investigated.

SETTING

Scottish University Hospital.

DESIGN

Thoracoscopy was performed in the bronchoscopy suite after premedication with atropine and papaveretum. Following a standard Abram's needle biopsy, the LTF thoracoscope was inserted through a flexible introducer (Olympus Optical Co Ltd; Tokyo, Japan). The pleura was inspected and biopsy specimens were taken of suspicious areas.

RESULTS

The final diagnosis was malignant pleural effusion in 16 of 24 patients. Ten of 16 were positive by Abram's biopsy, giving a sensitivity of 62%. Thirteen of 16 were positive by fiberoptic thoracoscopy, giving an improved sensitivity of 81%. The LTF thoracoscope was easy to use for pulmonologists experienced in rigid thoracoscopy and flexible bronchoscopy. Excellent views of the pleura were obtained from a single entry point. The procedure was well tolerated and no complications were encountered.

CONCLUSION

The LTF thoracoscope allows excellent pleural access but a larger biopsy channel (currently 2 mm) might increase the accuracy of diagnosis.

Для цитирования: McLean A N, Bicknell S R, McAlpine L G, Peacock A J. Investigation of pleural effusion: an evaluation of the new Olympus LTF semiflexible thoracofiberscope and comparison with Abram's needle biopsy.. Chest. 1998. DOI: 10.1378/chest.114.1.150.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.