m+Medelevator.RU
← Поиск публикаций
Drug design, development and therapy · 2026

Development and Validation of an HPLC-MS/MS Method for Determining BMS-1166, GB-1107, and Enzalutamide in Rat Plasma and Its Application to Pharmacokinetic Studies.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wang Shengnan, Lu Shijia, Li Guofei, Qi Yingjie

Аннотация

PURPOSE: Hepatocellular carcinoma (HCC) is a highly lethal malignancy with poor prognosis and limited clinical treatments. CD8⁺ T cell-based immunotherapy offers promising therapeutic potential against HCC. We fabricated MMP-9/pH dual-sensitive liposomes co-encapsulating enzalutamide, GB-1107 and BMS-1166 for HCC treatment. Reliable detection approaches are lacking to assess in vivo liposomal behavior. This study established an HPLC-MS/MS method for simultaneous determination of the three drugs in rat plasma, and applied it to characterize their pharmacokinetic profiles.

METHODS: The pH/MMP-9 dual-sensitive liposomes co-loaded with BMS-1166, GB-1107 and enzalutamide were prepared via the thin-film hydration method, and the resultant formulations exhibited satisfactory pharmaceutical properties meeting the predefined quality criteria. For chromatographic separation, a poroshell 120 EC-C18 column (50 × 4.6 mm, 2.7 μm) was adopted, combined with linear gradient elution of 0.1% formic acid in water and acetonitrile. Full validation of the established method was performed strictly following the guidelines for bioanalytical method validation as stated in the Chinese Pharmacopoeia.

RESULTS: BMS-1166, GB-1107, and enzalutamide exhibited good linearity over the concentration range of 1.0-1000.0 ng/mL. The accuracy and precision of BMS-1166, GB-1107, and enzalutamide all fall below 11.1%. In addition, the recoveries and matrix effect for these analytes ranged from 88.6%-99.7%. Pharmacokinetic results demonstrated that the prepared liposomes possessed favorable in vivo long-circulating properties, which prolonged the half-lives of BMS-1166 and GB-1107 by 25-fold and 13-fold, respectively, and enhanced their bioavailability by 35-fold and 30-fold, respectively. In contrast, no statistically significant effect was observed on enzalutamide.

CONCLUSION: The established method was validated and met the predefined quality criteria, thereby being suitable for investigating the in vivo pharmacokinetic profiles of BMS-1166, GB-1107, and enzalutamide.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты