OBJECTIVES

This study was designed to determine the clinical utility and feasibility of using 12.5-MHz ultrasound catheters for intracardiac echocardiography.

BACKGROUND

Intracardiac echocardiography is a potentially useful technique of cardiac imaging and monitoring in certain settings. The feasibility of intracardiac echocardiography using 20-MHz ultrasound catheters in patients has been demonstrated. High resolution images of normal cardiac structures as well as cardiac abnormalities have been obtained. However, imaging has been limited by the shallow depth of field inherent in high frequency ultrasound imaging.

METHODS

Intracardiac echocardiography with 12.5-MHz catheters was performed in eight mongrel dogs and 92 patients. Catheters were introduced percutaneously in 80 patients studied in the catheterization laboratory and directly into the heart in 12 patients in the operating room. Right heart imaging was performed in 68 patients and arterial and left heart imaging in 35 patients.

RESULTS

When these catheters were introduced into the venous system, the right atrium, tricuspid valve, right ventricle, pulmonary valve and pulmonary artery were visualized. Pericardial effusion, intracardiac masses and atrial septal defects were correctly identified. The left ventricle, left atrium, mitral valve, aortic valve, aorta and coronary arteries could be imaged from the arterial circulation. Diseases identified included valvular aortic stenosis, subvalvular aortic stenosis and Kawasaki disease. Average imaging time was 10 min. No complications occurred as a result of intracardiac echocardiography.

CONCLUSIONS

Intracardiac echocardiography with 12.5-MHz ultrasound catheters is safe and feasible; it also provides anatomic and physiologic information. This feasibility study provides a foundation for wider clinical use of intracardic echocardiography.

Для цитирования: Schwartz S L, Gillam L D, Weintraub A R, Sanzobrino B W, Hirst J A, Hsu T L, Fisher J P, Marx G, Fulton D, McKay R G. Intracardiac echocardiography in humans using a small-sized (6F), low frequency (12.5 MHz) ultrasound catheter. Methods, imaging planes and clinical experience.. Journal of the American College of Cardiology. 1993. DOI: 10.1016/0735-1097(93)90736-k.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.